Arctic Cat 120 Snowmobile Service Manual Download Hrg536sd honda manual.pdf Download Paguro 4000 owners manual.pdf Download Datsun 240z hls30 manual.pdf paguro 3000 manual Paguro 3000 Manual Paguro 3000 Boat diesel generator eBay Paguro 3000 Boat diesel generator in Vehicle Parts & Accessories, With this is also the original. Every product in the Paguro range is conceived, designed and manufactured, using bespoke components when required, to achieve the goal of reducing generator size while maximizing power and keeping sound to a minimum. Space is at a premium on modern boats, so with a Paguro, more yachts are able to enjoy the benefit of a generator than before. They list reference manuals and materials, components of the generator set, additional authorization list items, expendable supplies and materials, torque limits, and mandatory replacement parts. Refer to the Table of Contents (page i) for a complete list of the appendices used in this manual. HOW TO FIX A GENERATOR SET MALFUNCTION. Paguro generators are designed and manufactured with bespoke components, to ensure minimal size and footprint. Thanks to advanced technology, every Paguro generator is more compact, yet with the same energy performance. A manual safety commutator (on request), or an automatic safety commutator (on request) has to be provided. Note: Both the lines or at least the generator line only, have to be protected with a magneto thermic safety switch, fitted on the main board panel. For your PAGURO choose a: PAGURO 9000 If connected at: Bipolar: 230V 50Hz 32A 115V 60Hz 64A.

Download Hino 238, 258LP, 268, 338 series Service Manual PDF, This is the same type of service manual your local dealer will be used when doing a repair. With this service repair manual on hand can easily assist you in any repairs that you may need for your Hino 268 Machine.Manual contains step-by-step instruction, diagrams, illustration, disassembly,reassembly,and specifications to repair. Service Online service information is an alternative for our customers who are looking for cost effective repair information - but still want it direct from the manufacturer. Online subscriptions include: Engine, Chassis, Body Builder Information direct from Hino and Workshop Manuals.

Power Products » 2kW Military Tactical Generators

Pictured Left: 2kW 120V AC MTG P/N 95-531, Pictured Right: 2kW 28V DC MTG P/N 95-501 Download turnitin software free.

Paguro Generator Technical Manual

Since 1996 Dewey Electronics has been manufacturing and supplying the standard 2kW Military Tactical Generator to the US Department of Defense’s PM-Mobile Electric Power (PM-MEP). We have fielded over 17,000 MTGs in this open frame configuration.

Used by the tri-services (U.S. Army, U.S. Navy/U.S.M.C., and U.S. Air Force), it is supported with a full logistic package in the DoD inventory.

Our heavy fuel generators operate on diesel fuels and military fuels (JP-8) and meet all the requirements of Purchase Description PD 6115-0111, dated 1 February 2001.

Paguro Generator Technical Manual

These compact, portable, highly reliable, lightweight units are available with either 120V AC or 28V DC output and have established themselves as the mainstay of portable power for military applications worldwide. Their open frame configuration allows them to be easily lifted, stacked, or transported by any military vehicle. This open configuration contributes to the ease of maintenance for which these units are noted.

Equipped with a manual recoil starter and the ability to be electrically started from their NATO Slave Connector, these units are used throughout the military where pure military power is a requirement or when portability is a necessity. Now these units are available directly from Dewey Electronics.

The open frame configuration is available as follows:

Power OutputDewey ModelPM-MEP ModelNSNP/N
28V DC-501AMEP95-501A6115-01-435-156795-501
120V 60Hz-531AMEP95-531A6115-01-435-156595-531

Environmental Specification Summary The whisper game phrases for adults.

RequirementMil-Std-MEP-501AMEP-531A
High Temperature – Operation (Derated Power 1.9kW)705, TM 710.149°C/120°F49°C/120°F
Cold Temperature – Starting & Operating705, TM 701.1-40°C/-40°F-40°C/-40°F
705, TM 701.2-25°C/-13°F-25°C/-13°F
705, TM 701.4-5°C/+23°F-5°C/+23°F
Altitude (Full Rated Power 2kW)705, TM 720.11219 m @ 35°C 4000 ft @ 95°F1219 m @ 35°C 4000 ft @ 95°F
Altitude (Derated Power 1.6kW)705, TM 720.12438 m @ 35°C 8000 ft @ 95°F2438 m @ 35°C 8000 ft @ 95°F
Humidity705, TM 711.10-100%0-100%
Ice Glaze and Wind (tailored) (1.3 mm/0.5 inch) Ice glaze start & run one hourTemperature: Wind Speed:-23 to 0°C/-10 to 32°F 22.5 m/s (73 ft/s)-23 to 0°C/-10 to 32°F 22.5 m/s (73 ft/s)
Rain (tailored)100 mm (3.9 in/hr) 30 min/side with wind speed 18m/s (40 mph)3 hours exposure last hour operational per Mil-Std-705,TM 608.13 hours exposure last hour operational per Mil-Std-705, TM 608.1
Road (tailored) Truck or Trailer TransportationRoad Course:Distance:Speed:
Paved Highway250 miles/402 km50mph/80 km/hr
Perryman 1250 miles/402 km20 mph/32 km/hr
Churchville B125 miles/201 km20 mph/32 km/hr
Belgian Block15 miles/24 km20 mph/32 km/hr
Salt Fog (tailored –two 48 hour cycles)35°C/95°F5% solution5% solution
Sand and Dust (tailored 1.4 grams/m3 33.2 km/hr)Four 90 minute exposuresOperate last 10 minutes each exposureOperate last 10 minutes each exposure
Solar Radiation (tailored)One 24 hour cycle355 BTU/ft2355 BTU/ft2
Electromagnetic InterferenceTailored
Conducted Emissions (Power Leads)15 kHz to 2 MHz78/log(75/104)xlog(f/2)+60 dBµA/MHz78/log(75/104)xlog(f/2)+60 dBµA/MHz
2 MHz to 50 MHzWaived60 dBµA/MHz
Broadband Radiated Emissions14 kHz to 25 MHz25/log(56/105)x(log(f/25)+100 dBµV/MHz25/log(56/105)x(log(f/25)+100 dBµV/MHz
25 MHz to 80 MHz30/log(3125/104)xlog(f/25)+100 dBµV/MHz30/log(3125/104)xlog(f/25)+100 dBµV/MHz
80 MHz to 1 GHz70 dBµV/MHz70 dBµV/MHz
Radiated E-field2 to 400 MHz10 V/m10 V/m
400 MHz to 10 GHz5 V/m5 V/m

Physical Characteristics

Technical Manual Definition

DescriptionMEP-501AMEP-531A
Size29.5 inches X 16.0 inches X 21.7 inches29.5 inches X 16.0 inches X 21.7 inches
Weight140 lb with 4 hours of fuel152 lb with 4 hours of fuel
Instrument GagesAnalog VoltmeterAnalog Voltmeter
Analog Load MeterAnalog Load Meter
Analog Frequency Meter
Engine Hour MeterElectro-mechanical DigitalElectro-mechanical Digital
Circuit Breaker28V @ 82 Amps120V @ 20 Amps
ConnectorsNATO SLAVE ReceptacleNATO SLAVE Receptacle
TerminalsSplit Lug Load Terminals ( +/-)Split Lug Load Terminals (L/N)
ReceptacleGFCI Duplex 15 Amp